Siemens SINUMERIK 840Di Diagnostic Manual page 605

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
75608
Channel %1 RESU: NC memory limit reached, RAM type %2
Definitions:
A memory limit was reached on writing to file cc_resu.mpf. The possible area for return traveling is
shortened.
RAM type = 1: File cc_resu.mpf is created in the buffer memory (SRAM). The buffer memory is
therefore full. If the buffer memory is used and if alarm 75608 with RAM type 1 is output, system alarm
6500 will be output simultaneously.
RAM type = 2: The memory limit was reached on creating file cc_resu.mpf in the dynamic memory
(DRAM part program memory).
Reaction:
Alarm display.
Remedy:
RAM type = 1: Increase size of buffer memory ($MN_MM_USER_MEM_BUFFERED) or the available
space in the buffer memory, e.g. by unloading unused parts programs. Alternatively the ring buffer can
be decreased via MD $MC_RESU_RING_BUFFER_SIZE.
Program
Clear alarm with the Delete key or NC START.
Continuation:
75609
Channel %1 RESU: POS axis not permitted, axis type %2, block no. %3
Parameters:
%1 = Channel number
%2 = Axis type
%3 = Block number
Definitions:
A geometry axis is traversed as positioning axis at active CC_RREPRE.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
In order to traverse a geometry axis as positioning axis, RESU must be switched off temporarily (with
CC_PREPRE(0) ) or completely. In order to make the internal axis state change from the geometry
axis as positioning axis after traversing, a block without traveling motion must be programmed, if
required: e.g. X=IC(0)
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75610
Channel %1 RESU: NC start currently not possible
Definitions:
While RESU is active, no NC START must be performed in certain situations. If NC START is
confirmed nevertheless, execution will be blocked and alarm 75610 will be displayed. This applies in
the following situations:
On requesting return traveling: NC START is blocked when return traveling program cc_resu.mpf has
been created and selected.
After having triggered continuation under NC STOP condition: as long as the internally started block
search or the finally started Asup cc_resu_bs_asup.spf is running.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Wait for completion of the current internal procedure. Then delete the alarm with NC START and
continue
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-605

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents