Local link axis %1 is not allowed for different interpolation cycle time =
%2/%3
Parameters:
%1 = Axis name
%2 = Local interpolation cycle
%3 = Max. interpolation cycle
Definitions:
Local link axes are only permissible on an NCU if the interpolation cycle set corresponds to the slowest
interpolation cycle of the interconnected NCU systems.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Remove local link axis (see MN_AXCONF_MACHAX_NAME_TAB and
MN_AXCT_AXCONF_ASSIGN_TAB1) or adapt the interpolation cycle
(MN_IPO_SYSCLOCK_TIME_RATIO).
Program
Switch control OFF - ON.
Continuation:
4035
Interpolation cycle from NCU%1 = %2 does not match NCU%3 = %4
Parameters:
%1 = NCU_number1
%2 = MD value of NCU_number1
%3 = NCU_number2 (with slowest IPO cycle)
%4 = MD value of NCU_number2
Definitions:
Occurs only with an NCU link system. The interpolation cycles of the NCUs specified in the alarm do
not match one another. The slowest IPO cycle in interconnected NCU systems must be an integral
multiple of all configured IPO cycles.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Set a suitable value in MN_IPO_SYSCLOCK_TIME_RATIO for all interconnected NCUs.
Program
Switch control OFF - ON.
Continuation:
4036
Wrong NCU link configuration by MD %1
Parameters:
%1 = String: MD identifier
Definitions:
Occurs only with an NCU link system. Different interpolation and position control cycles have been set
in the NCUs of the LINK group. This is only allowed if the function FAST-IPO-LINK in MD
$MN_MM_NCU_LINK_MASK has been activated.
Caution: For diagnostic purposes, two additional alarm parameters are output together with this alarm.
- 1. 2nd parameter: Position control or IPO cycle time of this NCU
- 2. 2nd parameter: Position control or IPO cycle time of another NCU.
Reaction:
NC not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
- Activate FAST-IPO-LINK function in MN_MM_NCU_LINK_MASK
- Or do not set different position control or IPO cycles on the NCUs (see
MN_IPO_SYSCLOCK_TIME_RATIO and MN_POSCTRL_SYSCLOCK_TIME_RATIO).
Program
Switch control OFF - ON.
Continuation: