Axis %1 drive %2 rated power less than or equal to zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1130: $MD_MOTOR_NOMINAL_POWER (rated motor power) is less than or equal
to zero.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1130:
$MD_MOTOR_NOMINAL_POWER (rated motor power).
Program
Switch control OFF - ON.
Continuation:
300732
Axis %1 drive %2 rated speed less than or equal to zero
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1400: $MD_MOTOR_RATED_SPEED (rated motor speed) is less than or equal to
zero.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department.
For standard motors: Reset the drive (delete the bootfile) and repeat the startup.
For third-party motors: Check and, if necessary, refer to the motor data sheet to correct MD 1400:
$MD_MOTOR_RATED_SPEED (rated motor speed).