16773
Channel %1 axis %2 is the following axis. The axis/spindle disables of
leading axes %3 and %4 differ from one another.
Parameters:
%1 = Channel number
%2 = Axis, spindle
%3 = Axis, spindle
%4 = Axis, spindle
Definitions:
The axis is active in a coupling as a following axis. The master axes
have different states regarding axis/spindle disable.
The alarm can be suppressed with machine data 11415 SUPPRESS_ALARM_MASK_2 Bit0 =1.
Reaction:
Alarm display.
Remedy:
Set the same axis/spindle disable for all master axes.
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
16774
Channel %1 Synchronization aborted for slave axis/spindle %2
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
For the indicated axis, the synchronization procedure (EGONSYN or EGONSYNE) was aborted.
There are several reasons for aborting the synchronization process:
- RESET
- End of program
- Axis goes to follow-up mode
- Rapid stop caused by an alarm
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
If the abort of the synchronization procedure can be tolerated or is intended, the alarm can be
suppressed with machine data 11410 SUPPRESS_ALARM_MASK Bit31 = 1.
Only applicable for electronic gear (EG):
If it is not possible to abort the synchronization procedure, you can achieve it by specifying the block
change criterion FINE in EGONSYN or EGONSYNE.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
16776
Channel %1 block %2 curve table %3 does not exist for axis %4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of curve table
%4 = Axis name, spindle number
Definitions:
An attempt was made to couple axis %4 with curve table number %3, but no curve table of this number
exists.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify the NC part program so that the required curve table exists when axis link is to be activated.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition