Siemens SINUMERIK 840Di Diagnostic Manual page 819

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
400267
Access error
Definitions:
MCP or HHU data could not be accessed
Reaction:
Alarm display.
Remedy:
Check the MCP or HHU parameters of the FB1.
Program
Switch control OFF - ON.
Continuation:
400268
Error in internal communication with machine control panel 1, internal
error code: %Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check MCP parameter of FB1, MCP1Stop, switch TRUE->FALSE
Program
Switch control OFF - ON.
Continuation:
400269
Error in internal communication with machine control panel 2, internal
error code: %Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check MCP parameter of FB1, MCP2Stop, switch TRUE->FALSE
Program
Switch control OFF - ON.
Continuation:
400270
Error in internal communication with handheld unit, internal error code:
%Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check HHU parameter of FB1, HHUStop, switch TRUE->FALSE
Program
Switch control OFF - ON.
Continuation:
400271
Direct keys 1 communication error, internal error code: %Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check OpKey parameter
Program
Internal
Continuation:
400272
Direct keys 2 communication error, internal error code: %Z
Definitions:
Communication error between CP and PLC.
Reaction:
Alarm display.
Remedy:
Check OpKey parameter
Program
Internal
Continuation:
400274
Direct keys 1 failed
Definitions:
Direct keys 1: internal timeout has expired.
Reaction:
Alarm display.
Remedy:
Check connection to direct key module
Program
Internal
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
PLC alarms
2-819

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents