Overview of Alarms
NCK alarms
16916
Channel %1 repositioning: action %2<ALNX> not allowed in the current
state
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
Repositioning of block processing presently not possible. In certain cases this can prevent a mode
change from taking place.
The 2nd parameter describes which action should be used to perform repositioning.
Reaction:
Alarm display.
Remedy:
Let the program continue to a repositioned NC block or modify part program.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16918
Channel %1 for action %2<ALNX> all channels must be in reset state
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
All channels must be in the initial setting in order to carry out the action! (For example, for machine
data loading)
Reaction:
Alarm display.
Remedy:
Either wait until the channel status is aborted or press the Reset key.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16919
Channel %1 action %2<ALNX> is not allowed due to a pending alarm
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
This action cannot be performed due to an alarm, or the channel is in fail.
Reaction:
Alarm display.
Remedy:
Press RESET key.
Program
Clear alarm with the Delete key or NC START.
Continuation:
16920
Channel %1 action %2<ALNX> is already active
Parameters:
%1 = Channel number
%2 = Action number/action name
Definitions:
An identical action is still active.
Reaction:
Alarm display.
Remedy:
Wait until the first procedure is terminated or abort with Reset and repeat the operation.
Program
Clear alarm with the Delete key or NC START.
Continuation: