NCK alarms
14157
Channel %1 block %2 illegal interpolation type with MOVT
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Linear or spline interpolation must be active with MOVT (G0, G1, ASPLINE, BSPLINE, CSPLINE).
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14159
Channel %1 block %2 more than two angles programmed with ROTS or
AROTS
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Frame rotations are described using space angles with the language commands ROTS or AROTS. A
maximum of two angles can be programmed.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14160
Channel %1 block %2 tool length selection without geometry axis
specification
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If variant C (tool length acts on the programmed axis) is activated by machine data
$MC_TOOL_CORR_MODE for tool length compensation with H word and G43/G44 in ISO_2 mode,
at least one geometry axis must be specified.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Change machine data $MC_TOOL_CORR_MODE or the part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-222
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006