Siemens SINUMERIK 840Di Diagnostic Manual page 602

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
75260
RCTR: channel: %1, block: %2, tool parameters incorrect on block
editing
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
On block editing incorrect tool parameters are detected:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Correct tool parameters.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75265
RCTR: channel: %1, block: %2, unreachable position on block editing
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
On block editing a non-approachable position is detected:
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75270
RCTR: channel %1, tool parameters incorrect on interpolation
Parameters:
%1 = Channel number
Definitions:
On interpolation incorrect tool parameters are detected:
Reaction:
NC Start disable in this channel.
Alarm display.
NC Stop on alarm.
Remedy:
Correct tool parameters.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
75275
RCTR: channel: %1, block: %2, unreachable position on interpolation
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
On block interpolation a non-approachable position is detected:
Reaction:
NC Start disable in this channel.
Alarm display.
NC Stop on alarm.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-602
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006