10962
Channel %1 block %2 function %3 not possible with path correction
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Funktionsname
Definitions:
With this software release, the specified function can not yet be used together with tool radius
compensation. Please modifiy the part program or obtain a higher software version.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10980
Channel %1 block %2 orientation smoothing not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
This alarm can have the following causes:
1. Orientation smoothing cannot be activated with active path-relative orientation interpolation with
ORIPATH.
This means that in the 34th modal G code group
the G code OSOF must be active.
2. The path-relative orientation interpolation cannot be activated with ORIPATH and
ORIPATH_MODE = 1
because MD $MC_MM_ORIPATH_CONFIG = 0. This MD must have the value 1.
3. Smoothing of the orientation cannot be activated with OSD or OST
because MD $MC_MM_ORIPATH_CONFIG = 0. This MD must have the value 1.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
10982
Channel %1 block %2 orientation smoothing not possible with ORISON
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
This alarm has the following cause:
The smoothing of the orientation with ORISON is only possible if MD
$MC_MM_ORISON_BLOCKS >= 4.
Reaction:
Correction block is reorganized.
Interpreter stop
Interface signals are set.
Alarm display.
Remedy:
Modify part program or set MD $MC_MM_ORISON_BLOCKS >= 3.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation: