11/2006
15190
Channel %1 block %2 not enough free memory for subroutine call
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following deadlock has been found in the interpreter: Memory is needed for calling a subroutine.
The module memory is, however, empty and there is no prospect of module memory becoming free
again by executing the preprocessing/main run queue, because this queue is empty.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Increase machine data 28010
MM_NUM_REORG_LUD_MODULES/28040 MM_LUD_VALUES_MEM / 18210
MM_USER_MEM_DYNAMIC or program a preprocessing stop STOPRE before calling the
subroutine.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
15300
Channel %1 block %2 invalid number-of-passed-blocks during block
search
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In the function "Block search with calculation" a negative number of passes has been entered in
column P (number of passes). The permissible range of values is P 1 - P 9 999.
Reaction:
Alarm display.
Remedy:
Enter only positive number of passes within the range of values.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15310
Channel %1 block %2 file requested during block search is not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
During block search, a target has been specified with a program that has not been loaded.
Reaction:
Alarm display.
Remedy:
Correct the specified search target accordingly or reload the file.
Program
Clear alarm with the Delete key or NC START.
Continuation:
15320
Channel %1 block %2 invalid block search command
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The block search command (type of search target) is smaller than 1 or greater than 5. It is entered in
column type of the block search window. The following block search orders are allowed.
Type Meaning
1 Search for block number
2 Search for label
3 Search for string
4 Search for program name
5 Search for line number in a file
Reaction:
Alarm display.
Remedy:
Modify the block search command.
Program
Clear alarm with the Delete key or NC START.
Continuation:
© Siemens AG, 2006. All rights reserved