Siemens SINUMERIK 840Di Diagnostic Manual page 351

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
18004
Channel %1 block %2 orientation of workpiece-related protection zone
%3 does not correspond to the orientation of tool-related protection zone
%4
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Number of workpiece-related protection zone
Definitions:
The orientation of the workpiece-related protection zone and the orientation of the tool-related
protection zone differ. If the protection zone number is negative, then this is a global protection zone.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Modify the protection zone definition or do not simultaneously activate protection zones that have
different orientations.
- Check machine data and modify the protection zone definition if necessary.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
18005
Channel %1 block %2 serious error in definition of NCK-specific
protection zone %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Protection zone number
Definitions:
The protection zone definition must be terminated with EXECUTE before a preprocessing stop is
performed. This also applies to any that are initiated implicitly such as with G74, M30, M17.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
18006
Channel %1 block %2 serious error in definition of channel-specific
protection zone %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Protection zone number
Definitions:
The protection zone definition must be terminated with EXECUTE before a preprocessing stop is
performed. This also applies to any that are initiated implicitly such as with G74, M30, M17.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-351