Siemens SINUMERIK 840Di Diagnostic Manual page 198

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
14026
Channel %1 block %2 motion synchronous action: invalid polynomial
number in the FCTDEF command
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
An FCTDEF command was programmed with a polynomial number that exceeds the maximum value
set in $MC_MM_NUM_FCTDEF_ELEMENTS.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14027
Channel %1 block %2 motion-synchronous action: Too many technology
cycles programmed.
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
You can call a maximum of eight technology cycles with one motion-synchronous action. You
exceeded the upper limit.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14028
Channel %1 block %2 motion-synchronous action: Technology cycle
programmed with too many parameters
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Maximum number of transfer parameters for one technology cycle exceeded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Change technology cycle
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
14030
Channel %1 block %2 combine OSCILL and POSP during oscillation with
infeedmotion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
When oscillating controlled by synchronized actions, the assignment of oscillating and infeed axis
(OSCILL) as well as the definition of the infeed (POSP) must be carried out in one NC block.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
2-198
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006