Siemens SINUMERIK 840Di Diagnostic Manual page 870

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

System Reactions on Alarms
Names
NOREADY | NCKREACTIONVIEW
Effect
NCK ready off: Active rapid deceleration (i.e. with maximum braking current) of all drives
Clearing of servo enable for all NC axes Release of NC ready relay
− NC not ready
Names
NOREADY | BAGREACTIONVIEW
Effect
Mode group ready off: Active rapid deceleration (i.e. with maximum braking current) of
the drives in this mode group Clearing of servo enable for the NC axes concerned.
− Mode group not ready
Names
NOREADY
Effect
Channel ready off: Active rapid deceleration (i.e. with maximum braking current) of the
drives in this channel Clearing of servo enable for the NC axes concerned.
− Channel not ready
Names
NONCSTART
Effect
It is not possible to start a program in this channel.
− NC start inhibit in this channel
Names
NOREFMARK
Effect
The axes in this channel have to be rereferenced.
− Rereference axes in this channel.
Names
SETVDI
Effect
VDI interface signal alarm is set.
− Interface signals are set
Names
SHOWALARM
Effect
Alarm is displayed on MMC.
Alarm display
Names
STOPBYALARM
Effect
Ramp stop of all channel axes.
− NC stop for alarm
5-870
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006