Overview of Alarms
NCK alarms
10226
[up to SW 3.x only] Channel %1: reset aborted
Parameters:
%1 = Channel number
Definitions:
An error occurred during the reset, with the result that the sequence could not be continued.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Alarm display.
Remedy:
Press RESET again.
Program
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
Continuation:
10227
[up to SW 3.x only] Channel %1: command aborted
Parameters:
%1 = Channel number
Definitions:
An error occurred while a command was active, with the result that the sequence could not be
continued.
Reaction:
Alarm display.
Remedy:
Activate the command again.
Program
Clear alarm with the Delete key or NC START.
Continuation:
10230
[up to SW 3.x only] Mode group %2 channel %1 program interruption
does not permit mode change
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
While in the "program interrupted" status (interface signal DB 21 - 28, DBX 35.3) - triggered by an NC
Stop followed by a mode change to JOG - it is only possible to change back to the previous mode
(AUTOMATIC or MDI).
Reaction:
Alarm display.
Remedy:
You can change the mode via the "program aborted" status (interface signal DB 21 - 28, DBX 35.4) -
triggered by a "reset".
Program
Clear alarm with the Delete key or NC START.
Continuation:
10231
[up to SW 3.x only] Mode group %2 channel %1 program stop does not
permit mode change
Parameters:
%1 = Channel number
%2 = Mode group number
Definitions:
While in the "program stopped" status (interface signal DB 21 - 28, DBX 35.2, triggered by an NC
Stop), it is only possible to change back to continuous program operation (by means of an NC Start).
Reaction:
Alarm display.
Remedy:
You can change the mode via the "program aborted" status (interface signal DB 21 - 28, DBX 35.4) -
triggered by a "reset".
Program
Clear alarm with the Delete key or NC START.
Continuation:
2-100