Overview of Alarms
NCK alarms
16500
Channel %1 block %2 chamfer or rounding negative
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A negative chamfer or rounding has been programmed under the keywords CHF= ..., RND=... or
RNDM=...
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Values for chamfers, roundings and modal roundings must be programmed with positive values only.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16510
Channel %1 block %2 no facing axis for diameter programming available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Diameter programming has been activated although no transverse axis with diameter programming
has been applied.
Transverse axes can be applied with MD20100 or MD30460 bit2 for diameter programming.
Diameter programming can be applied through:
- basic position DIAMON or DIAM90 of the G 29 group during booting
- programming of DIAMON or DIAM90
- programming of DIAMONA[AX], DIAM90A[AX] or DAC, DIC, RAC, RIC
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
When programming DIAMON/DIAM90, a traverse axis must be configured via MD20100.
When programming DIAMONA[AX], DIAM90A[AX] or DAC, DIC, RAC, RIC, the AX axis must be a
transverse axis for diameter programming configured via MD30460 bit2.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16520
Channel %1 axis %2, diameter programming active, function %3 is not
executed
Parameters:
%1 = Channel
%2 = Axis, spindle
%3 = NC function
Definitions:
The function is not executed with diameter programming active for the stated axis.
The following functions may be affected:
1 - Axis interchange
2 - Axis container rotation
Reaction:
Interpreter stop
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Disable diameter programming of the axis before activating the function.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
2-286
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition