16600
Channel %1 block %2 spindle %3 gear stage change not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Spindle number
Definitions:
The programmed speed is outside the speed range of the set gear stage. In order to execute the
programmed speed, the gear stage must be changed. In order to be able to execute the automatic
gear stage change (M40 is active), the spindle must be in speed control operation.
>The alarm will no longer be output after having set bit 30 (0x40000000) in MD 11410
SUPPRESS_ALARM_MASK. However, the function will not be affected by this.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
The changeover to speed control operation is performed by programming M3, M4 or M5. The M
functions can be written together with the S word in the same block.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16670
Channel %1 block %2 following axis/spindle %3 maximum number of CP
modules (%4) has been exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules
Definitions:
An attempt was made to activate more generic couplings than are configured in MD18450.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Reduce the number of defined or active couplings, or increase the number of coupling modules
configured in MD18450.
If necessary, buy another option stage of the generic coupling.
Program
Clear alarm with NC START or RESET key and continue the program.
Continuation:
16671
Channel %1 block %2 following axis/spindle %3 maximum number of CP
modules (%4) has been exceeded
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
%4 = Max. number of CP modules
Definitions:
An attempt was made to activate more generic couplings than are configured in MD18450.
Reaction:
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Reduce the number of defined or active couplings, or increase the number of coupling modules
configured in MD18450.
If necessary, buy another option stage of the generic coupling.
Program
Clear alarm with the RESET key in all channels. Restart part program.
Continuation: