11/2006
4113
Sysclock cycle changed to %1 ms
Parameters:
%1 = String (new PLC cycle time)
Definitions:
MD 10050 SYSCLOCK_CYCLE_TIME has been modified on systems with PROFIBUS DP because
of the modified DP cycle in SDB-Type-2000.
Reaction:
Alarm display.
Remedy:
Machine data 10050 SYSCLOCK_CYCLE_TIME has been modified.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4114
Error in DP cycle of SDB-Type-2000
Parameters:
%1 = String (new PLC cycle time)
Definitions:
The DP cycle in SDB-Type-2000 contains an error and cannot be set. The default value of
$MN_SYSCLOCK_CYCLE_TIME is set.
Reaction:
Alarm display.
Remedy:
Correct SDB-Type-2000
Program
Switch control OFF - ON.
Continuation:
4115
Time ratio communication to Ipo changed to %1
Parameters:
%1 = String (new PLC cycle time)
Definitions:
The value of the machine data 10072 has been adapted. This can only occur, if the value of the
machine data is smaller than one and the time thus calculated is no multiple of the position control
cycle.
Reaction:
Alarm display.
Remedy:
The machine data $MN_COM_IPO_TIME_RATIO has been adapted. Please check to ensure that the
calculated value is correct.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4150
Channel %1 invalid M function subprogram call configured
Parameters:
%1 = Channel number
Definitions:
The machine data $MN_M_NO_FCT_CYCLE[n] or $MN_M_NO_FCT_CYCLE_PAR contains invalid
configration data: An M function, which is used by the system and can not be replaced by a
subprogram call has been specified in the machine data $MN_M_NO_FCT_CYCLE[n] for the
configuration of the subprogram call via M function:
- M0 to M5,
- M17, M30,
- M19, M40 to M45,
- M function for selecting spindle/axis mode according to $MC_SPIND_RIGID_TAPPING_M_NR
(default: M70),
- M functions for nibbling/punching as configured in $MC_NIBBLE_PUNCH_CODE if activated by
$MC_PUNCHNIB_ACTIVATION.
- Also M96 to M99 for applied external language ($MN_MM_EXTERN_LANGUAGE).
The machine data $MN_M_NO_FCT_CYCLE_PAR contains an invalid array index of
$MN_M_NO_FCT_CYCLE[n]. Currently, the values 0 to 9 are permissible. The affected machine data
is reset to the default value -1. This deactivates the function.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Configure an M function in the machine data $MN_M_NO_FCT_CYCLE[n] that is not assigned by the
system, or configure a permissible array index in the machine data $MN_M_NO_FCT_CYCLE_PAR.
Program
Switch control OFF - ON.
Continuation:
© Siemens AG, 2006. All rights reserved