11/2006
300858
Axis %1 drive %2 generator mode: response voltage > switch-off
threshold
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The sum of the values in MD1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator
axis) + MD1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) is greater
than MD1633: $MD_LINK_VOLTAGE_GEN_OFF (deactivation threshold for generator axis).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
Modify drive machine data
- Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
- Modify MD 1632: $MD_LINK_VOLTAGE_GEN_HYST (voltage range for generator control) or
- Modify MD 1633: $MD_LINK_VOLTAGE_GEN_OFF (voltage range for generator control) or
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
300859
Axis %1 drive %2 generator mode: response voltage > monitoring
threshold
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value in MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) is
greater than MD1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify MD 1631: $MD_LINK_VOLTAGE_GEN_ON (response voltage for generator axis) or
- Modify MD 1630: $MD_LINK_VOLTAGE_MON_THRESHOLD (response threshold for DC link
monitoring).
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation:
300860
Axis %1 drive %2 generator mode: emergency retraction speed > max.
motor speed
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The value entered for the emergency retraction speed in MD1639: $MD_RETRACT_SPEED
(emergency retraction speed) is greater than MD1146: $MD_MOTOR_MAX_ALLOWED_SPEED
(maximum motor speed).
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify MD 1639: $MD_RETRACT_SPEED (emergency retraction speed) or
- Modify MD 1146: $MD_MOTOR_MAX_ALLOWED_SPEED (maximum motor speed).
Program
Alarm display showing cause of alarm disappears. No further operator action necessary.
Continuation: