List of Action Numbers
No. 13
Explanation
Perform a rapid retraction (VDI signal: Digital-analog interface and ASUB interface, for
further actions see Nos. 10, 11, 12, 85, 86).
Cause
-
Remedy
-
No. 14
Explanation
Move tool - only with tool management (PI command).
Cause
-
Remedy
-
No. 15
Explanation
Perform deletion of distance-to-go or axis synchronization (VDI signal: deletion of dis-
tance-to-go or follow-up mode) (follow-up mode: e.g. on activation of axis motion).
Cause
1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program
No. 16
Explanation
Abort repetition of subroutine (VDI signal: Delete number of subroutine repetitions).
Cause
1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program
No. 17
Explanation
Abort subroutine processing (VDI signal: Program level abort).
Cause
1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy
Abort program
3-834
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006