Siemens SINUMERIK 840Di Diagnostic Manual page 538

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

Overview of Alarms
NCK alarms
61318
Channel %1 Block %2: Check weighting factor _K
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameter _K is 0. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994,
CYCLE998.
Remedy:
Check parameter _K.
61319
Channel %1 Block %2: Check call parameter CYCLE114
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Internal error in measuring cycles. Alarm is triggered: CYCLE974, CYCLE977, CYCLE978,
CYCLE979, CYCLE994, CYCLE998.
Remedy:
Check call parameter CYCLE114.
61320
Channel %1 Block %2: Check tool number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With active tool management, parameter _TNUM=0 and parameter _TNAME is not set or
the specified tool name of tool management is unknown.
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
Check parameter _TNUM, _TNAME.
61321
Channel %1 Block %2: Check WO memory number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
WO with the number specified in _KNUM not existing. Alarm is triggered: CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE994, CYCLE998.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check parameter _KNUM.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
61322
Channel %1 Block %2: Check 4th number of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy:
Check parameter _KNUM, _MVAR.
61323
Channel %1 Block %2: Check 5th number of _KNUM
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified position of _KNUM includes invalid values. Also check _MVAR.
Alarm is triggered: CYCLE974, CYCLE977, CYCLE978, CYCLE979, CYCLE994, CYCLE998,
CYCLE114.
Remedy:
Check parameter _KNUM, _MVAR.
2-538
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
11/2006

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents