Siemens SINUMERIK 840Di Diagnostic Manual page 537

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
61311
Channel %1 Block %2: No D number active
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No tool offset for the measuring probe (for workpiece measurement) or no tool offset for the active tool
(for tool measurement) is selected.
Alarm can be triggered by following measuring cycles: all measuring cycles.
Remedy:
Select the tool's tool edge number D.
61312
Channel %1 Block %2: Check measuring cycle number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
Measuring cycle called is impermissible...
61313
Channel %1 Block %2: Check probe number
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The probe has an impermissible value (_PRNUM).
The alarm can be triggered by the following measuring cycles: all measuring cycles.
Remedy:
Correct _PRNUM or create data field _TP[] or _WP[] for additional tool or workpiece probe
and adjust _CVAL[0]/_CVAL[1] accordingly.
61314
Channel %1 Block %2: Check selected tool type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm is triggered: CYCLE971, CYCLE972, CYCLE982.
Remedy:
Tool type impermissible for tool measurement/tool probe calibration.
61315
Channel %1 Block %2: Check position of cutting edge
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm is triggered: CYCLE972, CYCLE973, CYCLE974, CYCLE982, CYCLE994.
Remedy:
Check tool edge position (probe) in TO memory.
61316
Channel %1 Block %2: Center and radius cannot be determined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
No circle can be calculated from the measured points, as all measured points lie on a straight line.
The alarm is triggered by: CYCLE979
Remedy:
Program change
61317
Channel %1 Block %2: Check parameter CYCLE116
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Parameterization faulty; requires 3 or 4 points to calculate the center point. Alarm is triggered:
CYCLE979.
Remedy:
Change parameterization of CYCLE116.