Siemens SINUMERIK 840Di Diagnostic Manual page 579

Hide thumbs Also See for SINUMERIK 840Di:
Table of Contents

Advertisement

11/2006
62304
Channel %1 Block %2: Allowance
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The difference between actual and setpoint value is larger than upper tolerance limit (parameter
_TUL).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
62305
Channel %1 Block %2: Dimension too small
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE974, CYCLE977, CYCLE978, CYCLE979,
CYCLE994
Remedy:
The difference between actual and setpoint value is smaller than lower tolerance limit (parameter
_TLL).
62306
Channel %1 Block %2: Permissible measuring difference exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE982, CYCLE994
Remedy:
The difference between actual and setpoint value is larger than tolerance parameter _TDIF, tool data
are not corrected.
62307
Channel %1 block %2: Maximum number of characters per line
exceeded.
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105
Insufficient number of characters per line.
Remedy:
Increase the value in _PROTFORM[1]
62308
Channel %1 Block %2: Variable column width not possible
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm is triggerd by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Complete the header in _PROTVAL[0].
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
Overview of Alarms
NCK alarms
2-579