14098
Channel %1 block %2 conversion error: no valid number found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The string is not a valid INT or REAL number.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. If it is an entry, then you can check whether the string is a number via the preset
function ISNUMBER (with the same parameter).
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14099
Channel %1 block %2 result in string concatenation too long
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The result of string chaining returns a string which is greater than the maximum string length laid down
by the system.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Adapt part program. With the function STRLEN, it is also possible to test the size of the sum string
before performing the chaining operation.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
14100
Channel %1 block %2 orientation transformation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Up to 4 transformation groupings (transformation types) can be set for each channel via machine data.
If the keyword TRAORI(n) (n ... number of the transformation grouping) is used to address a
transformation grouping for which the machine data is not defaulted, the alarm message will be
triggered.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM
CORRECT. The correction pointer positions on the incorrect block.
- Check the number of the transformation grouping when calling the part program with the keyword
TRAORI(n) (n ... number of the transformation grouping).
- Enter the machine data for this transformation grouping and then activate by "Power On".
Program
Clear alarm with NC START or RESET key and continue the program.