11/2006
4050
NC code identifier %1 cannot be reconfigured to %2
Parameters:
%1 = String: Old identifier
%2 = String: New identifier
Definitions:
Renaming of an NC code was not possible for one of the following reasons:
- The old identifier does not exist
- The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reaction:
NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Correct machine data 10712:
NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier
e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT", NC_USER_CODE_CONF_NAME_TAB
[11] = " " clears the ROT function from the control
Program
Switch control OFF - ON.
Continuation:
4060
Standard machine data loaded (%1, %2)
Parameters:
%1 = Identifier 1
%2 = Identifier 2
Definitions:
The standard MD were loaded because
- a cold start was requested or
- the MD buffer voltage failed or
- an initialization was requested for loading the standard machine data (MD 11200 INIT_MD).
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. After automatically loading the standard
MDs, the individual MDs must be entered or loaded in the relevant system.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
4062
Backup data loaded
Definitions:
The user data saved in the flash memory are loaded to the SRAM.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Load specific machine data again.
Program
Clear alarm with the RESET key. Restart part program
Continuation:
© Siemens AG, 2006. All rights reserved