Generating An Exception List For Know-How Protection - Siemens Sinamics G110M Original Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for Sinamics G110M:
Table of Contents

Advertisement

Procedure
Proceed as follows to deactivate know-how protection:
1. Select the inverter in the STARTER
project, and using the right-hand
mouse button, open the dialog win-
dow "Know-how protection drive
device/deactivate ...".
2. There, select the desired option.
• Temporary status: Know-how
• Final status: If you select "Copy RAM to ROM", the inverter immediately deletes the
3. Enter the password and exit the screen form with OK.
You have deactivated know-how protection.
Changing the password
Select the inverter in the STARTER project, and open the dialog screen form using the
shortcut menu "Know-how protection drive device/change password ...".
9.4.2.2

Generating an exception list for know-how protection

Using the exception list, as machine manufacturer you can make individual adjustable
parameters accessible to end users although know-how protection is active. You may define
the exception list via parameters p7763 and p7764 in the expert list. Specify the number of
parameters for the selection list in p7763. Assign the individual indexes to the parameter
numbers of the selection list in p7764.
Procedure
Proceed as follows to change the number of parameters for the selection list:
1. Save the inverter settings via an upload (
2. In the project on the PC, set p7763 to the desired value.
3. Save the project.
4. Go online and load the project into the inverter (
5. Now make the additional settings in p7764.
You have modified the number of parameters for the selection list.
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
protection is active again after
switching the power supply off
and on.
password. If you do not select "Copy RAM to ROM", the inverter deletes the password
the next time the supply voltage is switched off.
Data backup and series commissioning
9.4 Write and know how protection
) on the PC/PG and go offline (
).
)
275