8.6.1

Extending the exception list for know-how protection

In the factory setting, the exception list only includes the password for know-how protection.
Before activating know-how protection, you can additionally enter the adjustable parameters in
the exception list, which must still be able to be read and changed by end users – even if know-
how protection has been activated.
You do not need to change the exception list, if, with exception of the password, you do not
require additional adjustable parameters in the exception list.

Absolute know-how protection

If you remove password p7766 from the exception list, it is no longer possible to enter or change
the password for know-how protection.
You must reset the converter to the factory settings in order to be able to gain access to the
converter adjustable parameters. When restoring the factory settings, you lose what you have
configured in the converter, and you must recommission the converter.
Parameter
Parameter
p7763
p7764[0...p7763]
SINAMICS G120X converter
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC
Name
CO: Torque limit upper / M_max upper
Reference speed reference frequency / n_ref f_ref
Reference voltage / Reference voltage
Reference current / I_ref
Reference torque / M_ref
Reference temperature / Ref temp
Fieldbus interface protocol selection / Fieldbus protocol
PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
PROFIdrive PZD telegram selection extended / PZD telegr ext
KHP OEM exception list number of indices for p7764 / KHP OEM qty p7765
KHP OEM exception list / KHP OEM excep list
Free tec_ctrl 0 unit selection / Ftec0 unit sel
Free tec_ctrl 1 unit selection / Ftec1 unit sel
Free tec_ctrl 2 unit selection / Ftec2 unit sel
Description
KHP OEM exception list, number of indices for p7764
KHP OEM exception list
p7766 is the password for know-how protection
Saving the settings and series commissioning
8.6 Know-how protection
Factory setting
1
[0] 7766
[1...499] 0
955