Parameters
7.1 Explanation of the detailed parameter list
Parameter name
The following abbreviations can appear in front of the names:
BI
BO
CI
CO
CO/BO
Can be changed
"-"
C(x)
U
T

Unit group and unit selection

For parameters where the unit can be switched over.
"Unit group": to which group does the parameter belong?
"Unit selection": with which parameter do you switch over the unit?

Data type

● Integer8
● Integer16
● Integer32
● Unsigned8
● Unsigned16
● Unsigned32
● FloatingPoint32

Scaling

Specification of the reference variable with which a signal value is automatically converted with
a BICO interconnection.
The following reference variables are available:
● p2000 ... p2003: Reference speed, reference voltage, etc.
● PERCENT: 1.0 = 100%
● 4000H: 4000 hex = 100 % (word) or 4000 0000 hex = 100 % (double word)
468
Binector input
Binector output
Connector input
Connector output
Connector/binector output
Interconnecting signals in the converter (Page 464)
The parameter can be changed in any state, and the change becomes imme‐
diately effective.
The parameter can only be changed for the following settings:
C: p0010 > 0
C(x): p0010 = x
The motor is switched on
The motor is switched off and p0010 = 0
I8
I16
I32
U8
U16
U32
Float
8-bit integer
16-bit integer
32-bit integer
8-bit without sign
16-bit without sign
32-bit without sign
32-bit floating-point number
Operating Instructions, 06/2019, FW V1.01, A5E44751209B AC