Setup & Operation 9. EMERGENCY

9. EMERGENCY

The details of safety requirements for this section are described in the User's Guide
NOTE
2. Safety. Please refer to them to keep the robot system safe.
■ Make sure that the emergency stop and safety door work properly before using
the system, not only when setting up the system, but also when the use
environment is changed.
CAUTION
Connect a safeguard switch or Emergency Stop switch to the Controller EMERGENCY
connector for safety.
When nothing is connected to the EMERGENCY connector, the robot system does not
operate normally.
■ Before connecting the connector, make sure that the pins are not bent.
Connecting with the pins bent may damage the connector and result in
malfunction of the robot system.
CAUTION

9.1 Safety Door Switch and Latch Release Switch

The EMERGENCY connector has input terminals for the
Emergency Stop switch. Be sure to use these input terminals to keep the system safe.
* The E-STOP BOX,
connector kit are offered as options.
52
EMERGENCY Connector
Connector
EMERGENCY connector
(Controller side)
EMERGENCY
Standard
D-sub 25 male pin
Mounting style #4 - 40
connector cable, terminal block, and
(Figure: RC700)
switch and the
Safety Door
EMERGENCY