Maintenance 9. Troubleshooting
No.
Message
Cannot execute in TEST mode
1054
except from TP.
Cannot execute the Background
1055
Task.
1056
Cannot execute from OP.
Cannot execute when TP3 enabled
1057
except from the TP3.
Cannot execute excluding T2
1058
mode.
1059
Cannot change to T2 mode.
1100
File failure. Cannot access the file.
File failure. Read and write failure
1102
of the registry
1103
File is not found.
1104
Project file was not found.
1105
Object file was not found.
1106
Point files were not found.
The program is using a feature that
1107
is not supported by the current
controller firmware version.
One or more source files are
1108
updated. Please build the project.
1109
Not enough storage capacity.
1110
File is not found.
1111
Conveyor file was not found.
Force files were not found.
1112
Rebuild the project.
Cannot create the project in the
1114
controller.
File failure.
1120
Setting file is corrupt.
File failure.
1121
Project file is corrupt.
File failure.
1122
Point file is corrupt.
File failure.
1123
I/O label file is corrupt.
File failure.
1124
User error file is corrupt.
File failure.
1126
Software option information is
corrupt.
File failure.
1127
Vision file is corrupt.
178
Remedy
-
Confirm that no background task is
running.
Rebuild the project.
Enable the TP3 input.
The command cannot be executed
from other consoles when TP3 is
enabled.
Switch to <Teach/T2> key.
T2 mode cannot be used on
RC700-A Controllers complying with
UL standards.
1. Reboot the controller.
2. Reinstall the firmware.
3. Replace the CF.
1. Reboot the controller.
2. Replace the CF.
Check whether the file exists.
Rebuild the project.
Rebuild the project.
Rebuild the project.
Check the compiler version in the
EPSON RC+
7.0-[Project]-[Properties]-[Compiler].
Rebuild the project.
Increase free space of the USB
memory.
-
-
Rebuild the project.
There is a possibility that the folder is
full or the project name is duplicated.
Check it by the application selection.
Restore the controller configuration.
Rebuild the project.
Rebuild the project.
Rebuild the project.
Rebuild the project.
1. Reboot the controller.
2. Reinstall the firmware.
3. Reconfigure the option.
Rebuild the project.
Note 1
Note 2
RC700 / RC700-A Rev.23