(8) Make sure that "No.2" is selected, and click the <Connect> button.
(9) After the development PC and Controller connection is completed, "Connected" is
Connection between the development PC and the Controller is complete. Now the robot
system can be used via an Ethernet connection from EPSON RC+ 7.0.
7.5 Disconnection of Development PC and Controller
with Ethernet
Disconnection of the development PC and the Controller is shown below.
(1) Display [PC-Controller Connection] dialog from [Setup] in EPSON RC+ 7.0 menu.
(2) Click the <Disconnect> button.
If the Ethernet cable is removed when the Controller and the development PC is connected,
NOTE
Emergency Stop occurs and the Robot stops. Be sure to click the <Disconnect> button in
the [PC to Controller Communications] dialog before the Ethernet cable is removed.
RC700 / RC700-A Rev.23
Setup & Operation 7. LAN (Ethernet Communication) Port
displayed in the [Connection status:]. Make sure that "Connected" is displayed and
click the <Close> button to close the [PC to Controller Communications] dialog.
Communication between the Controller and the development PC is disconnected and
the Ethernet cable can be removed.
49