3.3.2 AC Power Cable

Make sure that operations are done by a qualified personal.
Be sure to connect the earth wire (green/yellow) of the AC power cable to the
earth terminal of the factory power supply. The equipment must be grounded
properly at all times to avoid the risk of electric shock.
Always use a power plug or a disconnecting device for power connecting cable.
WARNING
Never connect the Controller directly to the factory power supply.
Select the plug or a disconnecting device which conform safety standards for
nations.
Make sure to insert the plug of the AC power cable firmly when connecting to the
Controller.
AC power wire (2 cables)
Ground wire
Cable length
Terminal
RC700 / RC700-A Rev.23
Item
Black, Black
or Black, White
Green / Yellow
3 m
M4 round solderless terminal
Specification