Maintenance 9. Troubleshooting
No.
Message
OBJ file size is large. TP1 may
3000
not be able to build this project.
The number of variables which is
3001
using Wait command is near the
maximum allowed.
3002
DLL file cannot be found.
3003
DLL function cannot be found.
3050
Main function is not defined.
3051
Function does not exist.
3052
Variable does not exist.
3100
Syntax error.
3101
Parameter count error.
File name length is beyond the
3102
maximum allowed.
3103
Duplicate function definition.
3104
Duplicate variable definition ' ** '.
Global and Global Preserve
3105
variables cannot be defined inside
a function block.
An undefined function was
3106
specified.
Both While and Until for Do...Loop
3107
was specified.
Specified line number or label ' ** '
3108
does not exist.
3109
Overflow error.
An undefined variable was
3110
specified ' ** '.
Specified variable is not an array
3111
variable.
Cannot change the dimensions of
3112
the array variable.
Specified Next variable does not
3114
match the specified For variable.
Cannot use a point expression in
3115
the first argument.
Array number of dimensions does
3116
not match the declaration.
212
Remedy
When it is necessary to build the
project from TP1, consider to reduce
the program.
The number of variables which is
using Wait command is exceeding 56
(the maximum is 64). Check if there
are unnecessary variables.
Check if the DLL file exists in either of
the following folders:
- Project folder
- Windows system folder
- Configuration folder of environment
variable PATH
Check the name of the specified
function. Also check the DLL file if
the specified function exists in the
DLL.
Declare a Main function.
Declare an unresolved function.
Declare an unresolved variable.
Correct the syntax error.
The number of parameters is excess
or deficiency. Correct the
parameters.
Shorten the file name.
Change the function name.
Change the variable name.
Declare the Global and Global
Preserve variables outside the
function block.
Specify a valid function name.
The While/Until statement is specified
for both Do statement and Loop
statement. Delete either While/Until
statement.
Set the line label.
The direct numerical specification
overflows. Reduce the numeric
value.
There is an undefined variable.
Declare the variable.
Specify the array variable.
Dimension of the array cannot be
changed in Redim statement during
the run time. Correct the program.
Correct the variable name.
Specify a single point for the point
flag setting. Do not specify a point
expression.
Check the number of array
dimensions.
Note 1