No.
Message
3606
Cannot use the index.
3607
Invalid object index was specified.
3608
Invalid control index was specified.
Modifier parameters are duplicated.
3609
Review the program.
Cannot use a keyword for a label
3610
name.
Vision Sequence Name or
3733
Calibration Name was not
specified.
3800
Compile process aborted.
3801
Link process aborted.
Compile process aborted.
3802
Compile errors reached the
maximum count.
Link process aborted. Link errors
3803
reached the maximum count.
Specified command cannot be
3804
executed from the Command
window.
Specified command can only be
3805
executed from the Command
window.
Specified function cannot be
3806
executed from the Command
window.
RC700 / RC700-A Rev.23
Remedy
Index number cannot be specified
except List property in GSet and
GGet statements. Correct the
program.
Invalid index is specified in Objects
property of VSet and VGet
statements. The index must be
larger than 1 and smaller than the
number of objects in the specified
sequence. Specify a proper index.
Invalid index is specified in Controls
property of GSet and GGet
statements. The index must be
larger than 1 and smaller than the
number of controls in the specified
form. Specify a proper index.
Force Guide data or CF parameter is
duplicated in CVMove, FCKeep or
other statement for robot motion.
Correct the program.
Keywords such as a command or a
function are used for a label name.
Change the label name which does
not use these keywords.
Vision sequence name or calibration
name is not specified in VSet and
VGet statements. Add a sequence
name or calibration name.
-
-
Correct the error in the program and
rebuild the project.
Correct the error in the program and
rebuild the project.
Declaration of variables and
functions, program control statement,
preprocessor commands, and some
commands cannot be executed from
the command window. For details,
refer to SPEL+ Language Reference
"Appendix A
SPEL+ Command Use
Condition List".
Brake, SysConfig, Where,
Cnv_QueList, and WorlQue_List
statements can only be executed
from the command window. Delete
these statements from the program.
LogIn function cannot be executed
from the command window even
when used with Print statement.
Use the function in the program.