No.
Message
Does not allow Operation mode to
1030
be changed.
Cannot execute while tasks are
1031
executing.
Cannot execute while the
1032
maximum number of tasks are
executing.
Cannot execute during
1033
asynchronous motion command.
Asynchronous command stopped
1034
during operation.
Cannot execute when Remote I/O
1035
enabled except from the remote
device.
Cannot execute when Remote
1037
Ethernet enabled except from the
remote Ethernet device.
1039
Execution is prohibited.
Cannot execute during Emergency
1041
Stop status.
Cannot execute while the
1042
safeguard is open.
Cannot execute during error
1043
condition.
Cannot execute when the remote
1044
pause input is ON.
Input waiting condition is the only
1045
available condition to input.
1046
Cannot execute during file transfer.
Cannot cancel the command
1047
executed from other devices.
Cannot execute after low voltage
1048
was detected.
Other devices are in program
1049
mode.
1050
Password is too long.
1051
Export Controller Status failed.
1052
Export Controller Status busy.
Execution in Test mode is
1053
prohibited
RC700 / RC700-A Rev.23
Remedy
Change to the Auto mode with a
console in the Program mode.
Stop the task and then execute.
Stop the task and then execute.
Execute after the motion ends.
The asynchronous command already
stopped when the controller received
a stop command.
The command cannot be executed
by the console except the remote I/O
when AutoMode output of the remote
I/O is ON.
The command cannot be executed
by the console except the remote
Ethernet when Auto flag of the
remote Ethernet is ON.
Prohibited command was executed
while executing the program.
Stop the program, and then execute
the command.
Cancel the Emergency Stop status.
Close the safeguard.
Cancel the error condition.
Change the remote pause input to
OFF.
The controller received an input while
it was not in the Input waiting
condition.
Execute after the file transmission.
Cancel the motion command from the
device the command was issued
from.
Reboot the controller.
Check connection of other devices.
Enter the password that is less than
16 characters.
1. Retry using the same USB
memory.
2. Retry using another USB
memory.
3. Retry after rebooting the
controller.
Execute the command after
completing the controller status
backup.
Execute in other modes.
Maintenance 9. Troubleshooting
Note 1
Note 2
177