Maintenance 9. Troubleshooting
No.
Message
3133
Cannot specify LimZ parameter.
3134
Cannot specify Sense parameter.
3135
Invalid parameter is specified.
Cannot specify the array variable
3137
subscript.
ByRef was not specified on
3138
Function declaration.
Cannot execute the Xqt statement
3139
for a function that needs a ByRef
parameter.
Cannot execute the Redim
3140
statement for a ByRef variable.
3141
OBJ file is corrupt.
OBJ file size is beyond the
3142
available size after compiling.
Indent length is beyond the
3143
available size.
' ** ' already used for a function
3144
name.
' ** ' already used for a Global
3145
Preserve variable.
' ** ' already used for a Global
3146
variable.
' ** ' already used for a Module
3147
variable.
' ** ' already used for a Local
3148
variable.
3149
' ** ' already used for an I/O label.
' ** ' already used for a User Error
3150
label.
3151
Cannot use a function parameter.
214
Remedy
LimZ parameter cannot be specified
in BGo, Go, TGo, Jump3, Arc, Arc3,
BMove, Move, and TMove
statements. Correct the program.
Sense parameter cannot be specified
in BGo, Go, TGo, Arc, Arc3, BMove,
Move, and TMove statements.
Correct the program.
Invalid parameter is specified in Xqt,
and Call statements. Correct the
program.
The array variable subscript cannot
be specified. Correct the program.
Specify ByRef in the parameter list of
function declaration that is called by
Call statement.
The Xqt statement cannot be
executed for a function needing a
ByRef parameter. Delete the ByRef
parameter.
The Redim statement cannot be
executed for a variable specifying
ByRef parameter. Delete the ByRef
parameter.
-
The compilation result exceeds the
limit value (max. 1 MB per file).
Divide the program.
The available length of the identifier is
max. 32 characters for labels and
variable names, and 64 characters for
function names. Reduce the
number of characters so as not to
exceed the available length. For
details of the available length, refer to
EPSON RC+ User's Guide "6.4
Function and Variable Names
(Naming restriction)".
Correct the identifier ' ** ' or the
function name.
Correct the identifier ' ** ' or the
Global Preserve variable name.
Correct the identifier ' ** ' or the
Global variable name.
Correct the identifier ' ** ' or the
Module variable name.
Correct the identifier ' ** ' or the Local
variable name.
Correct the identifier ' ** ' or the I/O
label name.
Correct the identifier ' ** ' or the User
Error label name.
Argument cannot be specified for the
function that is executed by the Trap
statement. Correct the program.
Note 1
Note 2
RC700 / RC700-A Rev.23