No.
Message
Command argument is out of the
available range. Check the
2264
arguments. Added data 1: Passed
value. Added data 2: argument
order.
Joint number is out of the available
2265
range.
2266
Wait time is out of available range.
Timer number is out of available
2267
range.
Trap number is out of available
2268
range.
Language ID is out of available
2269
range.
Specified D parameter value for the
2270
parallel process is out of available
range.
Arch number is out of available
2271
range.
Device No. is out of available
2272
range.
Output data is out of available
2273
range.
Asin argument is out of available
2274
range. Range is from -1 to 1.
Acos argument is out of available
2275
range. Range is from -1 to 1.
Sqr argument is out of available
2276
range.
Randomize argument is out of
2277
available range.
Sin, Cos, Tan argument is out of
2278
available range.
Timeout period set by the TMOut
statement expired before the wait
2280
condition was completed in the
WAIT statement.
Timeout period set by TMOut
2281
statement in WaitSig statement or
SyncLock statement expired.
Timeout period set by TMOut
2282
statement in WaitNet statement
expired.
Timeout.
2283
Timeout at display device setting.
RC700 / RC700-A Rev.23
Remedy
For available range of argument, see
the online help. Review the
program.
Available Joint number is from 1 to 6.
Review the program.
Available wait time is from 0 to
2147483. Review the program.
Available timer number is from 0 to
15. Review the program.
Available trap number is from 1 to 4.
Review the program.
For available language ID, see the
online help. Review the program.
Available D parameter value is from 0
to 100. Review the program.
Available arch number is from 0 to 7.
Review the program.
The specified number representing a
control device or display device is out
of available range. For available
device number, see the online help.
Review the program.
Available output data value is from 0
to 255. Review the program.
Review the program.
Review the program.
Review the program.
Review the program.
Review the program.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Investigate the cause of timeout.
Check whether the set timeout period
is proper.
Reboot the controller.
Maintenance 9. Troubleshooting
Note 1
The Added
value
The specified
joint number
The specified
wait time
The specified
timer number
The specified
trap number
The specified
language ID
The specified
D parameter
value
The specified
arch number
The specified
device
number
Output data
Timeout
period
Signal
number
Port number
Note 2
What
number
argument?
What
number byte
data is out of
range?
Timeout
period
Timeout
period