Emergency Stop, Safeguard (Euromap67 Board) - Epson RC700 Manual

Robot controller
Hide thumbs Also See for RC700:
Table of Contents

Advertisement

Setup & Operation 14. Option Slots

14.8.9 Emergency Stop, Safeguard (EUROMAP67 Board)

When the emergency stop switch is held down on the robot controller:
A function is used to communicate the emergency stop instruction to the IMM.
The emergency stop instruction is communicated using a safety relay. A deposition
detection function is also provided.
→ When deposition is detected, the robot controller will set the emergency stop
When an emergency stop occurs on the IMM side:
A function is used to communicate the emergency stop instruction to the robot
controller.
When the safety door has been opened on the IMM side:
A function is used to communicate the open safeguard instruction to the robot
controller.
EUROMAP67 Board: Overview of Emergency stop circuit
EUROMAP67 Board: Overview of Safety Door circuit
114
instruction communicated to the IMM to OPEN.