Setup & Operation 14. Option Slots
(3) Analog Input: Configuration
Channel
Input Mode
Voltage
Input Mode
ADC 1ch
Current
Input Mode
Voltage
Input Mode
ADC 2ch
Current
Input Mode
Channel
Input Mode
Voltage
Input Mode
ADC 1ch
Current
Input Mode
Voltage
Input Mode
ADC 2ch
Current
Input Mode
98
Voltage Current Switching Jumper (CN8/CN9): Current input/voltage input
1-2 pin short: Voltage input configuration
2-3 pin short: Current input configuration
Voltage Current Switching Switch (SWD1): Voltage/current input
Range Switching Switch (SWD3): Input range
SWD1(voltage current switching)
Range
Configuration
S1
±5.12V
±10.24V
Not
0 to 5.12V
Use
0 to 10.24V *
0 to 24mA
±5.12V
±10.24V
Not
0 to 5.12V
Use
0 to 10.24V *
0 to 24mA
Range
Configuration
S1
±5.12V
On
On
±10.24V
0 to 5.12V
Off
0 to 10.24V *
Off
0 to 24mA
Off
±5.12V
±10.24V
Not
0 to 5.12V
Use
0 to 10.24V *
0 to 24mA
*: Default: ADC default configuration (voltage input: 0 to 10.24V)
SWD1
SWD3
S1
S2
S3
S4
S2
S3
On
On
Not
Not
On
Use
Use
On
Off
Not
Not
Use
Use
Off
SWD3 (range switching)
S2
S3
On
Off
Not
Not
On
Use
Use
Off
On
On
On
On
Off
Not
Off
On
Use
Off
Off
Off
On
SWD4: Not used. Please turn them OFF.
SWD4
S1
S1
S2
S2
S3
S3
S4
S4
CN8
(voltage current
S4
switching)
1-2 short
1-2 short
1-2 short
1-2 short
2-3 short
On
On
On
Not Use
On
SWD4
S4
Off
Off
RC700 / RC700-A Rev.23
CN9
(voltage
current
switching)
Not Use
1-2 short
1-2 short
1-2 short
1-2 short
2-3 short

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc700-a