No.
Message
2521
File path is too long.
2522
File name is invalid.
The continue process was already
2523
executed.
Cannot execute Xqt when the
2524
specified trap number is already
executing.
2525
Password is invalid.
2526
No wait terms.
Too many variables used for global
2527
variable wait.
The global variable that was not
2528
able to be used for the wait
command was specified.
Cannot use ByRef if the variable is
2529
used for global variable wait.
2530
Too many point files.
The point file is used by another
2531
robot.
Cannot progress to the point
2532
position because there is undefined
data.
2533
Error on INP or OUTP.
No main function to start for Restart
2534
statement.
Does not allow Enable setting in
2535
Teach mode to be changed.
Failed to change Enable setting in
2536
Teach mode.
Count of point data P(:) is not
2537
correct or format of parameter is not
correct.
Force_GetForces failure.
2538
Failed to process Force_GetForces
statement.
2539
Password is invalid.
2540
Not connected to RC+.
2541
Duplicate parameter.
The specified work queue number
2542
is invalid.
2543
Invalid sequence was specified.
2544
Invalid object was specified.
2545
Invalid calibration was specified.
Cannot turn on the motor
2546
immediately after opening the
safeguard.
Too many force files.
2548
Delete the force files or use the
existing force files.
RC700 / RC700-A Rev.23
Remedy
Check whether the specified point file
name is correct.
Make sure you don't use improper
characters for file name.
Review the program.
Review the program.
Check whether a password is set
correctly.
Rebuild the project.
Review the program.
Review the program.
Review the program.
Check the point file.
Review the program.
Check the point data.
Review the program.
Without executing main function,
Restart is called.
Setup the authority.
Reboot the Controller.
Review the program.
Review the program.
Check the password.
Connect to the RC+.
Same robot number was specified.
Check the parameter.
Available work queue number s are
from 1 to 16. Review the program.
Specified sequence name cannot be
found. Review the sequence name.
Specified object name cannot be
found. Review the object name.
Specified calibration name cannot be
found. Review the calibration name.
Wait 1.5 seconds after the safeguard
is open, and then execute the motor
on.
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
Maintenance 9. Troubleshooting
Note 1
Note 2
203