NOTE
Delete files that do not relate to the project before transfer.
This function is used to send the data to the system director and EPSON from the end
users for problem analysis.

6.4 Details of Data

The following data files are created by the Controller backup function.
Backup.txt
CurrentMnp01.PRM Robot parameter
CurrentStatus.txt
ErrorHistory.csv
InitFileSrc.txt
MCSys01.MCD
SrcmcStat.txt
ProjectName.obj
GlobalPreserves.dat
MCSRAM.bin
MCSYSTEMIO.bin
MCTABLE.bin
MDATA.bin
SERVOSRAM.bin
VXDWORK.bin
WorkQueues.dat
All files related to
project except
ProjectName.obj *1
*1 Storage of "All files related to project except ProjectName.obj" can be specified by a
setting.
RC700 / RC700-A Rev.23
File Name
Information file
for restore
Save status
Error history
Initial setting
Robot setting
Hardware
information
OBJ file
Global Preserve
variables
Inner information
of Robot operation
WorkQue
information
Project
Setup & Operation 6. Memory Port
Outline
File with information for Controller restore.
Saves information such as ToolSet.
Saves program and I/O status.
Saves various settings of the Controller.
Saves information of connected robot.
Saves installation information of hardware.
Result of project build.
Prg file is not included.
Saves values of Global Preserve variables.
Saves information of Queues information of
the WorkQue.
Select EPSON RC+ 7.0 menu-[Setup]-
[System Configuration] to display the
[System Configuration] dialog.
When [Include project files when status
exported] check box is checked in
[Controller]-[Preferences], the project file is
stored.
Includes program files.