Maintenance 9. Troubleshooting
No.
Message
Fieldbus slave. Timeout error
7103
occurred during I/O data transform.
Fieldbus master.
7150
Bus is disconnected.
7151
Fieldbus master. Bus power is off.
Fieldbus master.
7152
Bus status error.
7200
Invalid argument.
7201
A system error occurred.
7202
There is not enough memory.
7203
Access is denied.
7210
Drive is not ready.
7211
The specified path is invalid.
7212
The specified path already exists.
The file specified by path does not
7213
exist.
7214
File size is too large.
7215
The specified file is open.
7216
The open mode is illegal.
7217
There is no read data.
7230
The specified connection is open.
A connection-level error occurred
7231
while opening the connection.
7232
The connection is closed.
An unsupported data type was
7233
used.
7234
Data size is too large.
The specified file type is not
7235
supported.
7236
There is no selected data.
7250
No bytes were available to read.
7251
The port is in an invalid state.
7252
The specified port is open.
7253
The port is closed
7254
The specified port is not open.
7255
Timeout reading from the port.
276
Remedy
The fieldbus slave board is broken or
the controller software is damaged.
Restore the controller firmware.
A communication data error was
detected during communication.
The communication cable has a
problem. Check the communication
cable and its related units.
Check the connection of the
communication cable for the fieldbus.
Check whether the communication
cable for the fieldbus is powered.
Reboot the controller.
Check the fieldbus master board.
Replace the fieldbus master board.
Check the parameter.
-
-
-
Set the device.
Make sure the specified path exists.
If the specified directory or file
already exists, you cannot execute.
Make sure the specified file exists.
Specify the file that is less than 2G
bytes.
The specified file number is already
existing. Use another file number.
Make sure you opened in reading or
writing mode.
Make sure there are data to read.
The specified file number is already
existing. Use another file number.
Check the access right of database.
Use OpenDB and open the database.
Convert the data into string or
numeric value.
Too large data in a line. Specify the
query so that necessary field are only
retrieved.
Check the type of Excel file.
Make sure the data you retrieved
exists.
There are no retrieved data. Check
the send program.
Check the device setting for the
specified port.
Check the port number to open.
Check the port number to close.
Check the port number to open.
Check the port timeout period and
update to the appropriate setting.
Note 1
Note 2
1
2
3
4
RC700 / RC700-A Rev.23