Maintenance 9. Troubleshooting
No.
Message
Cannot specify Force Coordinate
3880
System Object label.
Review the program.
Cannot specify Force Control
3881
Object label.
Review the program.
Cannot specify Force Monitor
3882
Object label.
Review the program.
Cannot specify Force Trigger
3883
Object label.
Review the program.
Cannot specify Force Sensor
3884
Object label.
Review the program.
Cannot specify Mass Property
3885
Object number.
Review the program.
Cannot specify Force Coordinate
3886
System Object number.
Review the program.
Cannot specify Force Control
3887
Object number.
Review the program.
Cannot specify Force Monitor
3888
Object number.
Review the program.
Cannot specify Force Trigger
3889
Object number.
Review the program.
Cannot specify Force Sensor
3890
Object number.
Review the program.
Type of the specified two objects
does not match.
3891
Specify the same type of the
objects.
Cannot obtain the internal
3900
communication buffer.
3901
Buffer size is not enough.
Undefined command was
3910
specified.
Cannot enter the file name in the
3911
file name buffer.
Cannot obtain the internal buffer.
3912
Cannot set priority.
3913
3914
Invalid ICode.
3915
Invalid ICode.
3916
Invalid ICode.
236
Remedy
Force coordinate system object label
cannot be specified in FDel and FList
statements.
Correct the program.
Force control object label cannot be
specified in FDel and FList
statements.
Correct the program.
Force monitor object label cannot be
specified in FDel and FList
statements.
Correct the program.
Force trigger object label cannot be
specified in FDel and FList
statements.
Correct the program.
Reboot the controller.
Initialize the controller firmware.
Replace the controller.
Mass property object number cannot
be specified in MPNumber function.
Correct the program.
Force coordinate system object
number cannot be specified in
FNumber function.
Correct the program.
Force control object number cannot
be specified in FNumber function.
Correct the program.
Force monitor object number cannot
be specified in FNumber function.
Correct the program.
Force trigger object number cannot
be specified in FNumber function.
Correct the program.
-
The data type of the first and the
second parameter does not match in
FDel, FList, MPDel, MPList
statements.
Correct the program.
-
-
-
-
-
Reboot the controller.
Rebuild the project.
Rebuild the project.