2 Parameters
2.2 List of parameters
p0429[0...n]
Encoder SSI configuration / Enc SSI config
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: C(4)
Unit group: -
Min
-
Description:
Sets the configuration for an SSI encoder.
Bit field:
Bit
00
02
06
Notice:
This parameter is automatically pre-set for encoders from the encoder list (p0400).
When selecting a catalog encoder, this parameter cannot be changed (write protection). Information in p0400 should
be carefully observed when removing write protection.
Note:
For bit 06:
The quiescent signal level of the data line corresponds to the inverted, set level.
p0430[0...n]
Sensor Module configuration / SM config
Access level: 3
Can be changed: C(4)
Unit group: -
Min
-
Description:
Sets the configuration of the Sensor Module.
Bit field:
Bit
20
21
25
27
Notice:
A bit-wise configuration is only possible if the corresponding property is also present in r0458.
Note:
For bit 20 (speed calculation mode):
- if bit = 1, the speed is calculated via incremental difference without extrapolation.
- if bit = 0, the speed is calculated via edge time measurement with extrapolation. p0453 is effective in this mode.
For bit 21 (zero mark tolerance):
- if bit = 1, a one-off zero mark distance error is tolerated. In the event of a defect, the fault F3x100/F3x101 does not
appear, but alarm A3x400/A3x401 does.
For bit 25 (disconnect the encoder power supply on parking):
- if bit = 1, the encoder power supply is switched off on parking (0 V).
- if bit = 0, the encoder power supply is not switched off on parking, it is reduced from 24 V to 5 V.
For bit 27 (extrapolate position values):
- if bit = 1, the extrapolation of the position values is activated.
p0432[0...n]
Gearbox factor encoder revolutions / Grbx_fact enc_rev
Access level: 3
Can be changed: C(4)
Unit group: -
Min
1
Description:
Sets the encoder revolutions for the gearbox factor of the encoder evaluation.
The gearbox factor specifies the ratio between the encoder shaft and motor shaft (for motor encoders) or between
the encoder shaft and the load.
84
Signal name
Transfer code
Transfer absolute value twice
Data line during the monoflop time
Signal name
Speed calculation mode (only SMC30)
Zero mark tolerance
Switch off encoder voltage supply during
parking
Extrapolate position values
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Binary code
Yes
High level
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Incremental diff
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
1048576
Data type: Unsigned16
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0000 0000 bin
0 signal
Gray code
No
Low level
Data type: Unsigned32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
0000 0000 0000 0000 0000 0000 0000
0000 bin
0 signal
Flank time meas
No
No
No
Data type: Integer32
Dyn. index: EDS, p0140
Func. diagram: -
Factory setting
1
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
FP
-
-
-
FP
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f

Table of Contents