p2901[0...n]
CO: Fixed value 2 [%] / Fixed value 2 [%]
Access level: 3
Can be changed: U, T
Unit group: -
Min
-10000.00 [%]
Description:
Setting and connector output for a fixed percentage value.
Dependency:
Refer to: p2900, p2930
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can be used to interconnect a scaling function (e.g. scaling of the supplementary setpoint)
r2902[0...14]
CO: Fixed values [%] / Fixed values [%]
Access level: 3
Can be changed: -
Unit group: -
Min
- [%]
Description:
Display and connector output for frequently used percentage values.
Index:
[0] = Fixed value +0 %
[1] = Fixed value +5 %
[2] = Fixed value +10 %
[3] = Fixed value +20 %
[4] = Fixed value +50 %
[5] = Fixed value +100 %
[6] = Fixed value +150 %
[7] = Fixed value +200 %
[8] = Fixed value -5 %
[9] = Fixed value -10 %
[10] = Fixed value -20 %
[11] = Fixed value -50 %
[12] = Fixed value -100 %
[13] = Fixed value -150 %
[14] = Fixed value -200 %
Dependency:
Refer to: p2900, p2901, p2930
Note:
The signal sources can, for example, be used to interconnect scalings.
p2930[0...n]
CO: Fixed value M [Nm] / Fixed value M [Nm]
Access level: 3
Can be changed: U, T
Unit group: -
Min
-100000.00 [Nm]
Description:
Setting and connector output for a fixed torque value.
Dependency:
Refer to: p2900, p2901, r2902
Notice:
A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note:
The value can, for example, be used to interconnect a supplementary torque.
r2969[0...6]
Flux model value display / Psi_mod val displ
Access level: 3
Can be changed: -
Unit group: -
Min
-
Description:
Displays the values of the direct access flux model for the synchronous reluctance motor (RESM) for diagnostic
purposes.
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
10000.00 [%]
Calculated: -
Scaling: PERCENT
Unit selection: -
Max
- [%]
Calculated: -
Scaling: p2003
Unit selection: -
Max
100000.00 [Nm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
2 Parameters
2.2 List of parameters
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 1021
Factory setting
0.00 [%]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 1021
Factory setting
- [%]
Data type: FloatingPoint32
Dyn. index: DDS, p0180
Func. diagram: 1021
Factory setting
0.00 [Nm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: -
Factory setting
-