Siemens SINAMICS G120D CU240D-2 DP Manual page 416

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

2 Parameters
2.2 List of parameters
Note:
It is not permissible that the value is less than the sum of the "energy-saving mode transition time" and the "operating
state transition time" (system properties).
Pe: PROFIenergy profiles
p5606[0...1]
Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: T
CU250D-2_PN_F
Unit group: -
Min
0 [ms]
Description:
Sets the time of maximum stay for the energy-saving mode.
Index:
[0] = Mode 1
[1] = Reserved
Note:
Pe: PROFIenergy profiles
p5611
Pe energy-saving properties general / Pe properties gen
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: T
CU250D-2_PN_F
Unit group: -
Min
-
Description:
Sets the general properties for energy-saving.
Bit field:
Bit
00
01
02
Note:
Pe: PROFIenergy profiles
PROFIdrive state S4: operation
p5612[0...1]
Pe energy-saving properties mode-dependent / Pe properties mod
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: T
CU250D-2_PN_F
Unit group: -
Min
-
Description:
Sets the mode-dependent properties for energy-saving.
Index:
[0] = Mode 1
[1] = Reserved
Bit field:
Bit
00
01
02
Note:
Pe: PROFIenergy profiles
r5613.0...1
CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU240D-2_PN
Access level: 3
CU240D-2_PN_F
Can be changed: -
CU250D-2_PN_F
Unit group: -
Min
-
Description:
Display and binector output for the state display PROFIenergy energy saving active or inactive.
416
Signal name
Inhibit PROFIenergy control commands
Drive initiates OFF1 when transitioning to
energy-saving mode
Trans to energy-saving mode from
PROFIdrive state S3/S4 poss
Signal name
Reserved
Shutdown digital outputs
Shutdown encoder supply
Calculated: -
Scaling: -
Unit selection: -
Max
4294967295 [ms]
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
1 signal
Yes
Yes
Yes
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2381
Factory setting
4294967295 [ms]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 2381, 2382
Factory setting
0000 bin
0 signal
No
No
No
Data type: Unsigned32
Dyn. index: -
Func. diagram: -
Factory setting
[0] 0110 bin
[1] 0000 bin
0 signal
No
No
No
Data type: Unsigned8
Dyn. index: -
Func. diagram: 2382
Factory setting
-