Siemens SINAMICS G120D CU240D-2 DP Manual page 153

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

17:
20:
21:
22:
23:
26:
27:
30:
31:
32:
33:
36:
37:
60:
61:
62:
63:
66:
67:
70:
71:
72:
73:
76:
77:
Dependency:
When changing this parameter, the following settings are influenced:
Refer to: p1070, p1071, p1075, p1076
Caution:
If p1000 is selected as the main setpoint of the fieldbus, the following BICO interconnection is set automatically:
p2051[1] = r0063
Notice:
The parameter is possibly protected as a result of p0922.
For PROFIBUS/PROFINET Control Units, the following applies: The parameter can be freely set by setting p0922 =
999.
When executing a specific macro, the corresponding programmed settings are made and become active.
p1000[0...n]
Speed setpoint selection / n_set sel
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
0
Description:
Sets the source for the speed setpoint.
For single-digit values, the following applies:
The value specifies the main setpoint.
For double-digit values, the following applies:
The left-hand digit specifies the supplementary setpoint, the right-hand digit the main setpoint.
Example:
Value = 26
--> The analog setpoint (2) supplies the supplementary setpoint.
--> The fieldbus (6) supplies the main setpoint.
Value:
0:
1:
3:
6:
10:
11:
13:
16:
30:
31:
33:
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
Motor potentiometer + analog setpoint 2
Analog setpoint + no main setpoint
Analog setpoint + motor potentiometer
Analog setpoint + analog setpoint
Analog setpoint + fixed speed setpoint
Analog setpoint + fieldbus
Analog setpoint + analog setpoint 2
Fixed speed setpoint + no main setpoint
Fixed speed setpoint + motor potentiometer
Fixed speed setpoint + analog setpoint
Fixed speed setpoint + fixed speed setpoint
Fixed speed setpoint + fieldbus
Fixed speed setpoint + analog setpoint 2
Fieldbus + no main setpoint
Fieldbus + motor potentiometer
Fieldbus + analog setpoint
Fieldbus + fixed speed setpoint
Fieldbus+fieldbus
Fieldbus + analog setpoint 2
Analog setpoint 2 + no main setpoint
Analog setpoint 2 + motor potentiometer
Analog setpoint 2 + analog setpoint
Analog setpoint 2 + fixed speed setpoint
Analog setpoint 2 + fieldbus
Analog setpoint 2 + analog setpoint 2
No main setpoint
Motorized potentiometer
Fixed speed setpoint
Fieldbus
Motor potentiometer + no main setpoint
Motor potentiometer + motor potentiometer
Motor potentiometer + fixed speed setpoint
Motor potentiometer + fieldbus
Fixed speed setpoint + no main setpoint
Fixed speed setpoint + motor potentiometer
Fixed speed setpoint + fixed speed setpoint
Calculated: -
Scaling: -
Unit selection: -
Max
66
2 Parameters
2.2 List of parameters
Data type: Integer16
Dyn. index: CDS, p0170
Func. diagram: -
Factory setting
0
153

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120d cu250d-2 pn-fSinamics g120d cu240d-2 pnSinamics g120d cu240d-2 pn-fSinamics g120d cu250d-2 dp-f