Siemens SINAMICS G120D CU240D-2 DP Manual page 687

Sinamics g120d cu240d-2 series; sinamics g120d cu250d-2 series
Hide thumbs Also See for SINAMICS G120D CU240D-2 DP:
Table of Contents

Advertisement

0
Automatic mode Ramp-function generator active
1
Mop configuration
2
p1030 [D] (0000 0110 bin)
3
Ramp-function generator is always active
4
STW setpoint chan
p1035
r1198
1 = Motorized potentiometer,
r1198
.13
[2505.7]
setpoint, raise
STW setpoint chan
p1036
r1198
1 = Motorized potentiometer,
r1198
.14
[2505.7]
setpoint, lower
MotP n_max
p1037 [D] (0.000)
<1>
MotP n_min
p1038 [D] (0.000)
<1>
<1>
For automatic commissioning, p1037 and p1038 are set to the maximum motor speed (p0322) or to the
rated motor speed (p0311), provided that the maximum motor speed has not been specified.
<2>
If initial rounding-off is active (p1030.2 = 1), the selected ramp-up/down times are exceeded
accordingly.
<3>
Only effective if p1030.0 = 0.
1
2
Setpoint channel
Motorized potentiometer
Data save active
0
The setpoint for the motorized potentiometer is not saved and after ON is entered using p1040.
1
The setpoint for the motorized potentiometer is saved in a ashion after OFF and after ON set to the saved value.
0
Without ramp-function generator in automatic mode (ramp-up/ramp-down time = 0).
1
With ramp-function generator in automatic mode.
Initial rounding-off active
0
Without initial rounding.
1
With initial rounding. The ramp-up/down time set is exceeded accordingly.
Save in NVRAM active
0
Not saved in the NVRAM (NVRAM = Non Volatile Random Access Memory).
1
Save in NVRAM active.
0
Ramp-up encoder inactive with pulse inhibit.
1
The ramp-up encoder is calculated independently of the pulse enable.
0
Old value is kept
-1
1
Mop manual/auto
p1041 [C]
0 0
0 1
0
-1
1
1 0
1 1
MotP inv
p1039 [C]
(0)
Mop auto setpoint
p1042 [C]
(0)
3
4
p1030.1
&
(0)
0.000 ... 1000.000 [s]
Mop n_set bef RFG [rpm]
r1045
0
1
x
1
0
Reference value for the ramp-
function generator
[3050.8]
Mop set val
p1044 [C]
(0)
MotP acc set val
p1043 [C]
(0)
[2634.8] 1: OFF1 enable missing (r0046.0)
0:
5
fp_3020_97_51.vsd
09.12.2015
<2>
<2>
Mop ramp-up time
Mop ramp-down time
0.000 ... 1000.000 [s]
p1047 [D] (10.000)
p1048 [D] (10.000)
y
p1082
y
x
-p1082
y = 0
Mop start value
-210000.000 ... 210000.000 [rpm]
p1040 [D] (0.000)
<3>
p1030.4
0
1
6
7
Function diagram
SINAMICS G120D
V4.7.6
Mop setp after
RFG [rpm]
r1050
e.g. to [3030.1]
8
- 3020 -