2 Parameters
2.2 List of parameters
BI: p2658 = 1 signal
The position actual value received via CI: p2657 is valid.
BI: p2658 = 0 signal
The position actual value received via CI: p2657 is invalid.
Dependency:
Refer to: r2526, p2657
Note:
While a 0 signal is present, the position setpoint (p2665) is held at the value of 0.
p2659
BI: EPOS referencing active feedback signal / Ref act fdbk
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the feedback signal "referencing active".
BI: p2659 = 1 signal
Referencing is active.
BI: p2659 = 0 signal
Referencing is not active.
Dependency:
Refer to: r2526
p2660
CI: EPOS measured value referencing / Meas val ref
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the measured value for the function "referencing".
Dependency:
Refer to: r2523
p2661
BI: EPOS measured value valid feedback signal / MeasVal valid fdbk
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the feedback signal "measured value valid".
BI: p2661 = 1 signal
The measured value received via CI: p2660 is valid.
BI: p2661 = 0 signal
The measured value received via CI: p2660 is invalid.
Dependency:
Refer to: r2526, p2660
p2662
BI: EPOS adjustment value valid feedback signal / Adj val valid FS
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the feedback signal "adjustment value valid".
BI: p2662 = 1 signal
The adjustment value received via CI: p2660 is valid.
BI: p2662 = 0 signal
The adjustment value received via CI: p2660 is not valid.
374
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612
Factory setting
2526.1
Data type: U32 / Integer32
Dyn. index: -
Func. diagram: 3612, 3614
Factory setting
2523[0]
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 3612, 3614, 3615
Factory setting
2526.2
Data type: U32 / Binary
Dyn. index: -
Func. diagram: -
Factory setting
2526.9
SINAMICS G120D