2 Parameters
2.2 List of parameters
Dependency:
Refer to: p2543, p2544, r2684
Refer to: F07451
Note:
The following applies for the setting of the standstill and positioning monitoring time:
Standstill monitoring time (p2543) <= positioning monitoring time (p2545)
p2546[0...n]
LR dynamic following error monitoring tolerance / s_delta_monit tol
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: U, T
Unit group: -
Min
0 [LU]
Description:
Sets the tolerance for the dynamic following error monitoring.
If the dynamic following error (r2563) exceeds the selected tolerance, then an appropriate fault is output.
Value = 0 --> The dynamic following error monitoring is de-activated.
Dependency:
Refer to: r2563, r2684
Refer to: F07452
Note:
The tolerance bandwidth is intended to prevent the dynamic following error monitoring incorrectly responding due to
operational control sequences (e.g. during load surges).
p2547
LR cam switching position 1 / Cam position 1
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: U, T
Unit group: -
Min
-2147483648 [LU]
Description:
Sets the cam switching position 1.
Dependency:
Refer to: p2548, r2683
Caution:
Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note:
Position actual value <= cam switching position 1 --> r2683.8 = 1 signal
Position actual value > cam switching position 1 --> r2683.8 = 0 signal
p2548
LR cam switching position 2 / Cam position 2
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: U, T
Unit group: -
Min
-2147483648 [LU]
Description:
Sets the cam switching position 2.
Dependency:
Refer to: p2547, r2683
Caution:
Only after the axis has been referenced can it be guaranteed that the cam switching signals when output have a
"true" position reference.
Note:
Position actual value <= cam switching position 2 --> r2683.9 = 1 signal
Position actual value > cam switching position 2 --> r2683.9 = 0 signal
p2549
BI: LR enable 1 / Enable 1
CU250D-2_PN_F
Access level: 1
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for the position controller enable 1.
Dependency:
Refer to: r0899, p2550
344
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
2147483647 [LU]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: Unsigned32
Dyn. index: DDS, p0180
Func. diagram: 4025
Factory setting
1000 [LU]
Data type: Integer32
Dyn. index: -
Func. diagram: 4025
Factory setting
0 [LU]
Data type: Integer32
Dyn. index: -
Func. diagram: 4025
Factory setting
0 [LU]
Data type: U32 / Binary
Dyn. index: -
Func. diagram: 4015
Factory setting
899.2
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313