2 Parameters
2.2 List of parameters
Note:
For OFF1/OFF3, the ramp-function generator ramp is effective.
The ramp-function generator is set (to the setpoint (r1170)) and stops the drive corresponding to the ramp-down time
(p1121 or p1135). While stopping via the ramp-function generator, STW1.4 is effective (enable ramp-function
generator).
p1160[0...n]
CI: Speed controller speed setpoint 2 / n_ctrl n_set 2
CU250D-2_PN_F
Access level: 3
CU250D-2_DP_F
Can be changed: T
Unit group: -
Min
-
Description:
Sets the signal source for speed setpoint 2 of the speed controller.
Dependency:
Refer to: p1155, r1170
Note:
For OFF1/OFF3, the ramp-function generator ramp is effective.
The ramp-function generator is set (to the setpoint (r1170)) and stops the drive corresponding to the ramp-down time
(p1121 or p1135). While stopping via the ramp-function generator, STW1.4 is effective (enable ramp-function
generator).
When the function module "position control" (r0108.3 = 1) is activated, this connector input is interconnected as
follows as standard:
CI: p1160 = r2562
r1169
CO: Speed controller speed setpoints 1 and 2 / n_ctrl n_set 1/2
Access level: 4
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Displays the speed setpoint after the addition of the speed setpoint 1 (p1155) and speed setpoint 2 (p1160).
Dependency:
Refer to: p1155, p1160
Note:
The value is only correctly displayed at r0899.2 = 1 (operation enabled).
r1170
CO: Speed controller setpoint sum / n_ctrl setp sum
Access level: 3
Can be changed: -
Unit group: 3_1
Min
- [rpm]
Description:
Display and connector output for the speed setpoint after selecting the ramp-function generator.
The value is the sum of speed setpoint 1 (p1155) and speed setpoint 2 (p1160).
Dependency:
Refer to: r1150, p1155, p1160
r1197
Fixed speed setpoint number actual / n_set_fixed No act
Access level: 4
Can be changed: -
Unit group: -
Min
-
Description:
Displays the number of the selected fixed speed/velocity setpoint.
Dependency:
Refer to: p1020, p1021, p1022, p1023
Note:
If a fixed speed setpoint has not been selected (p1020 ... p1023 = 0, r1197 = 0), then r1024 = 0 (setpoint = 0).
182
Calculated: -
Scaling: p2000
Unit selection: -
Max
-
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: p2000
Unit selection: p0505
Max
- [rpm]
Calculated: -
Scaling: -
Unit selection: -
Max
-
Data type: U32 / FloatingPoint32
Dyn. index: CDS, p0170
Func. diagram: 3001, 3080
Factory setting
2562[0]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3080
Factory setting
- [rpm]
Data type: FloatingPoint32
Dyn. index: -
Func. diagram: 3001, 3080, 6300
Factory setting
- [rpm]
Data type: Unsigned32
Dyn. index: -
Func. diagram: 3010
Factory setting
-
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313